Thursday, August 27, 2020

2010 Cadillac Truck Escalade/ESV RWD V8-6.2L Page 282

2010 Cadillac Truck Escalade/ESV RWD V8-6.2L Page 282

Conditions for Setting the DTC

The HVAC control module detects the signal circuit is less than 5 counts or greater than 250 counts.

Action Taken When the DTC Sets

* The driver information center (DIC) will display SERVICE A/C SYSTEM.

* The system will operate as if no sunload condition exists.

Conditions for Clearing the DTC

* The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.

* The history DTC will clear after 100 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Automatic)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air

Temperature Description and Operation)

* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air Delivery

Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Verification

Ignition ON, observe the appropriate scan tool Sunload Sensor parameter. The reading should be between 5 and 250 counts and change with

sunlight intensity.

Circuit/System Testing

Important: If a solar load sensor has an out of range condition caused by a short to voltage, short to ground, or an open/high resistance,

the scan tool will display the same value: 225 counts.

1. Ignition OFF, disconnect the harness connector at the sunload sensor.

2. Test for less than 10 ohms between the ground circuit terminal C and ground.

瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.

3. Ignition ON, test for 4.8-5.2 volts between the ground circuit terminal C and the appropriate signal circuit terminal listed below:

* Left solar load sensor circuit terminal A.

* Right solar load sensor circuit terminal B.

瀚慖f less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the

HVAC control module.

瀚慖f greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control

module.

4. If all circuits test normal, test or replace the sunload sensor.