Saturday, December 7, 2019

2010 Cadillac Truck Escalade AWD V8-6.2L Page 1105

Circuit/System Verification

1. Verify that DTCs P0A95, P0C77, and P1A20 is not set.

锟斤拷If any of the DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle (See: Diagnostic Trouble Code

Descriptions/Diagnostic Trouble Code (DTC) List - Vehicle).

2. Verify that DTC P0ABD is not set.

锟斤拷If the DTC is set, replace the drive motor generator battery assembly. If the DTC resets, replace the drive motor generator battery control

module.

3. Ignition ON, engine OFF, observe the scan tool Hybrid Battery Pack Calculated and Hybrid Battery Terminal parameters. The readings

should be between 169 and 408 V and should be within 50 V of each other.

Circuit/System Testing

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal

Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

* Identify how to disable high voltage.

* Identify how to test for the presence of high voltage.

* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must

be followed.

Failure to follow the procedures exactly as written may result in serious injury or death.

1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling ().

2. Connect the 12 V battery.

Note: The following tests require wearing personal protection equipment (PPE) gloves.

3. Ignition ON, engine OFF, command the high voltage negative contactor closed with a scan tool. Test for less than 0.5 ohm between the high

voltage negative contactor terminals X2 and X3.

锟斤拷If greater than the specified range, replace the negative contactor relay.

4. Command the high voltage positive contactor closed with a scan tool. Test for less than 0.5 ohm between the high voltage positive contactor

terminals X2 and X3.

锟斤拷If greater than the specified range, replace the positive contactor relay.

5. Ignition OFF, test for less than 5 ohm between the high voltage negative contactor terminal X2 and the drive motor generator battery negative

terminal.

锟斤拷If greater than the specified range, replace the drive motor negative relay cable.

6. Test for less than 5 ohm between the high voltage positive contactor terminal X2 and drive motor generator battery positive terminal.

锟斤拷If greater than the specified range, replace the drive motor positive relay cable.

7. Disconnect the X5 harness connector at the drive motor generator battery control module.

8. Test for less than 5 ohm between the high voltage negative contactor terminal X3 and the ground terminal 5 X5.

锟斤拷If greater than the specified range, replace the drive motor battery positive and negative cable.

9. Test for less than 5 ohm between the high voltage positive contactor terminal X3 and drive motor generator battery control module terminal 1

X5.

锟斤拷If greater than the specified range, replace the drive motor positive and negative cable.

10. Disconnect the X4 harness connector at the drive motor generator battery control module.

11. Connect the EL-48571 high voltage battery pin out box.

12. Install the high voltage manual disconnect lever. Measure and record each of the 20 battery voltages.

13. Each battery voltage reading should be between 10-19 V.