Action Taken When the DTC Sets

* DTCs P0A1B and P0A1C are Type A DTCs.

* The PIM commands the battery energy control module (BECM) to open the high voltage contactor relays.

Conditions for Clearing the DTC

DTCs P0A1B and P0A1C are Type A DTCs.

Reference Information

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions (See: Diagnostic Trouble Code Descriptions/Powertrain Diagnostic Trouble Code

(DTC) Type Definitions)

Circuit/System Verification

1. Clear the DTC information.

2. Ignition OFF for 1 minute.

3. Ignition ON.

4. Retest for DTCs P0A1B and P0A1C.

Circuit/System Testing

Program the PIM with the latest software version and recheck for DTCs.

If the DTC resets after programming or if the PIM already contains the latest software version, replace the PIM.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

Control Module References (See: Testing and Inspection/Programming and Relearning) for PIM replacement, setup, and programming.

P0A1C

DTC P0A1B or P0A1C

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System

Check - Vehicle) prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an

overview of the diagnostic approach.

* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure

Instructions) provides an overview of each diagnostic category.

DTC Descriptor

DTC P0A1B

- Drive Motor 1 Control Module Performance

DTC P0A1C

- Drive Motor 2 Control Module Performance

Circuit/System Description

This is a fault detection of the Drive Motor Generator Power Inverter Modules' (PIM) internal Motor Control Module (MCM). This fault is handled

inside the PIM and no external circuits are involved. The MCMs are located within the PIM and are not serviced separately.

Conditions for Running the DTC

* The control module runs the program to detect an internal fault when the ignition is ON.

* Ignition voltage is 8-18V.

Conditions for Setting the DTC

The control module has detected an internal malfunction.