Wednesday, November 13, 2019

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 2971

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 2971

* ECM X 3 terminal 53 and PIM X 1 terminal 11

* ECM X 3 terminal 33 and PIM X 1 terminal 10

瀚慖f greater than the specified range, test the circuit for open/high resistance

7. If all circuits test normal, replace the PIM.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

* GMLAN Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Wiring Repairs/GMLAN Wiring Repairs)

* Control Module References (See: Testing and Inspection/Programming and Relearning) for module replacement, setup, and programming

U1816

DTC U1816

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System

Check - Vehicle) prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an

overview of the diagnostic approach.

* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure

Instructions) provides an overview of each diagnostic category.

DTC Descriptor

DTC U1816 00

- Lost Communication With Drive Motor Control Module "B" on Bus "B"

Diagnostic Fault Information

Circuit/System Description

Modules connected to the high speed hybrid GMLAN serial data circuits monitor for serial data communications during normal vehicle operation.

Operating information and commands are exchanged among the modules. The modules have prerecorded information about what messages are

needed to be exchanged on the serial data circuits, for each virtual network. The messages are supervised and also, some periodic messages are

used by the receiver module as an availability indication of the transmitter module. Each message contains the identification number of the

transmitter module.

The communication enable and the wakeup circuits are energized by a specific module to activate another specific module when the ignition key is

in ACC, ON or START. Only the modules using high speed GMLAN serial data are connected to the enable or wakeup circuits. Refer to the

schematics to determine which modules activate and are activated using the enable or wakeup circuits.

The motor control module (MCM) 1, 2, and the hybrid powertrain control module (HPCM) are all internal to the drive motor power inverter

module (PIM). The MCMs communicate only with the HPCM with the HPCM sending out DTC information to other modules regarding the

MCMs. All circuits to the MCM are also internal to the PIM and is replaced as a single component.

Communication diagnostics for the serial data, including module power and ground as well as the wakeup circuits for both MCMs, and the HPCM

are all diagnosed from external sources only to the PIM connector because any circuit fault condition within the PIM will cause a complete

replacement.