DTC P0056

- HO2S Heater Control Circuit Bank 2 Sensor 2

DTC P0059

- HO2S Heater Resistance Bank 2 Sensor 1

DTC P0060

- HO2S Heater Resistance Bank 2 Sensor 2

DTC P0135

- HO2S Heater Performance Bank 1 Sensor 1

DTC P0141

- HO2S Heater Performance Bank 1 Sensor 2

DTC P0155

- HO2S Heater Performance Bank 2 Sensor 1

DTC P0161

- HO2S Heater Performance Bank 2 Sensor 2

Diagnostic Fault Information

Typical Scan Tool Data

Circuit/System Description

Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding

air with the oxygen content in the exhaust stream. The HO2S must reach operating temperature to provide an accurate voltage signal. A heating

element inside the HO2S minimizes the time required for the sensors to reach operating temperature. Voltage is provided to the heater by an

ignition voltage circuit through a fuse. With the engine running, ground is provided to the heater by the HO2S heater low control circuit through a

low side driver within the engine control module (ECM). The ECM uses pulse width modulation (PWM) to control the HO2S heater operation to

maintain a specific HO2S operating temperature range.

Conditions for Running the DTC

P0030, P0036, P0050, or P0056

* The ignition 1 voltage is between 11-18 volts.

* The engine speed is greater than 400 RPM.

* The DTCs run continuously when the above conditions are met for 1 second.

P0053, P0054, P0059, or P0060

* DTCs P0112, P0113, P0117, P0118, or P2610 are not set.

* The engine run time is greater than 3 seconds.

* The ignition voltage is less than 18 volts.

* The ignition is OFF for greater than 8 hours.