Saturday, October 12, 2019

2019 Cadillac Truck Escalade AWD V8-6.2L Diagnostic Instructions Page 680


* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning)for scan tool information



Circuit/System Verification



Ignition ON, command the appropriate actuator in both directions with a scan tool. The scan tool door position parameter reading should be between



3 and 253 counts.



Circuit/System Testing



1. Ignition OFF, disconnect the harness connector at the appropriate actuator.



2. Test for less than 10 ohms between the low reference circuit terminal 7 and ground.



锟斤拷 If greater than the specified range, test the low reference circuit for an open/high resistance.



3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 10 and ground.



锟斤拷 If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance.



锟斤拷 If greater than the specified range, test the 5-volt reference circuit for a short to voltage.



4. Verify the appropriate scan tool parameter is greater than 250 counts.



锟斤拷 If greater than the specified range, test the signal circuit terminal 9 for a short to ground.



5. Install a 3-amp fused jumper wire between the signal circuit terminal 9 and the low reference circuit terminal. Verify the appropriate scan tool



parameter is less than 4 counts.



锟斤拷 If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance.



6. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 5 and ground.



锟斤拷 If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.



7. Install a DMM between the actuator control circuit terminal 6 and ground. While monitoring the DMM, use the scan tool to command the



appropriate actuator from one direction to the other. The voltage on the control circuit should move from 0 volts in one direction to 5 volts in



the other direction and 2.5 volts in the at rest state.



锟斤拷 If the voltage does not change, test the control circuit for an open, short to voltage or short to ground. If circuit tests normal replace the



HVAC control module.



8. If all circuits test normal, replace the actuator.



Repair Instructions



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.



* Air Inlet Valve Actuator Replacement (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and Repair/HVAC -



Automatic/Air Inlet Valve Actuator Replacement)



* Mode Valve Actuator Replacement (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and Repair/HVAC -



Automatic/Mode Valve Actuator Replacement)



* Temperature Valve Actuator Replacement - Left Side (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and



Repair/HVAC - Automatic/Temperature Valve Actuator Replacement - Left Side)



* Temperature Valve Actuator Replacement - Right Side (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and



Repair/HVAC - Automatic/Temperature Valve Actuator Replacement - Right Side)



* Auxiliary Temperature Valve Actuator Replacement (Behr) (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service



and Repair/HVAC - Automatic/Auxiliary Temperature Valve Actuator Replacement (Behr))Auxiliary Temperature Valve Actuator



Replacement (Delphi) (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and Repair/HVAC -



Automatic/Auxiliary Temperature Valve Actuator Replacement (Delphi))



* Auxiliary Mode Valve Actuator Replacement (Behr) (See: Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and



Repair/HVAC - Automatic/Auxiliary Mode Valve Actuator Replacement (Behr))Auxiliary Mode Valve Actuator Replacement (Delphi) (See:



Heating and Air Conditioning/Air Door/Air Door Actuator / Motor/Service and Repair/HVAC - Automatic/Auxiliary Mode Valve Actuator



Replacement (Delphi))



* Control Module References (See: Testing and Inspection/Programming and Relearning)for HVAC control module replacement, setup, and