Conditions for Setting the DTC
The HVAC control module detects the signal circuit is less than 5 counts or greater than 250 counts.
Action Taken When the DTC Sets
* The driver information center (DIC) will display SERVICE A/C SYSTEM.
* The system will operate as if no sunload condition exists.
Conditions for Clearing the DTC
* The DTC will become history if the HVAC control module no longer detects the condition that set the DTC.
* The history DTC will clear after 100 fault-free ignition cycles.
Reference Information
Schematic Reference
HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Automatic)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Description and Operation
* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air
Temperature Description and Operation)
* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air Delivery
Description and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
Ignition ON, observe the appropriate scan tool Sunload Sensor parameter. The reading should be between 5 and 250 counts and change with sunlight
intensity.
Circuit/System Testing
Important: If a solar load sensor has an out of range condition caused by a short to voltage, short to ground, or an open/high resistance, the
scan tool will display the same value: 225 counts.
1. Ignition OFF, disconnect the harness connector at the sunload sensor.
2. Test for less than 10 ohms between the ground circuit terminal C and ground.
锟斤拷 If greater than the specified range, test the ground circuit for an open/high resistance.
3. Ignition ON, test for 4.8-5.2 volts between the ground circuit terminal C and the appropriate signal circuit terminal listed below:
* Left solar load sensor circuit terminal A.
* Right solar load sensor circuit terminal B.
锟斤拷 If less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the
HVAC control module.
锟斤拷 If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control
module.
4. If all circuits test normal, test or replace the sunload sensor.