HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Manual)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Description and Operation
* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Manual/Air
Temperature Description and Operation)Air Temperature Description and Operation
* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Manual/Air Delivery
Description and Operation)Air Delivery Description and Operation
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning)for scan tool information
Circuit/System Verification
1. Ignition ON, disconnect the harness connector at the auxiliary HVAC control module, test for 4.8-5.2 volts between the 5-volt reference
circuit terminal 3 and ground.
锟斤拷 If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal,
replace the HVAC Control Module.
锟斤拷 If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the HVAC
Control Module.
2. Reprogram the HVAC control module that set DTC B1023. The module should successfully reprogram.
锟斤拷 If the module will not reprogram, replace the HVAC control module that set the DTC.
3. With a scan tool, clear the DTC.
4. Ignition OFF.
5. Wait 60 seconds, then recheck for DTCs. DTC B1023 should not set.
锟斤拷 If DTC B1023 sets, replace the module.
Repair Instructions
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
Control Module References (See: Testing and Inspection/Programming and Relearning)Control Module References for control module
replacement, setup, and programming
B1024
DTC B1024
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System
Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an
overview of the diagnostic approach.
* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure
Instructions) provides an overview of each diagnostic category.