Friday, May 3, 2019

2019 Cadillac Truck Escalade AWD V8-6.2L Diagnostic Instructions Page 218


Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning)for scan tool information



Circuit/System Verification



1. Ignition ON, doors unlocked, transaxle in Park, enable the power liftgate by pressing the liftgate enable/disable button on the I/P switch



assembly.



2. Open the liftgate by pressing the touchpad on the liftgate handle switch. The liftgate should release and power open.



3. Close the liftgate by pressing the liftgate button switch. The liftgate should power close, cinch-in, and latch.



Circuit/System Testing



1. Ignition OFF, disconnect the X3 harness connector at the K39 liftgate control module.



2. Test for less than 15 ohm between the control terminal 14 at the K39 liftgate control module and ground.



锟斤拷 If greater than the specified range, replace the K39 liftgate control module.



3. Test for less than 15 ohm between the control terminal 13 at the K39 liftgate control module and ground.



锟斤拷 If greater than the specified range, replace the K39 liftgate control module.



4. Test for 9-10 ohm between the control circuit terminal 13 and control circuit terminal 14 at the liftgate motor assembly.



锟斤拷 If less than the specified range, test either control circuit for a short to ground. If the circuits test normal, replace the M17 liftgate motor



assembly.



锟斤拷 If greater than the specified range, test either control circuit for a short to voltage or an open/high resistance. If the circuits test normal,



replace the M17 liftgate motor assembly.



5. If all circuits test normal, replace the M17 liftgate motor assembly.



Repair Instructions



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.



* Liftgate Close Actuator Motor Replacement (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Trunk / Liftgate Motor/Service



and Repair/Liftgate Close Actuator Motor Replacement)



* Control Module References (See: Testing and Inspection/Programming and Relearning)for liftgate control module replacement,



programming, and setup



B396F



DTC B396F



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.



DTC Descriptors



DTC B396F 06



- Liftglass Ajar Output Signal Circuit Short to Ground or Open



DTC B396F 0B



- Liftglass Ajar Output Signal Circuit Current Above Threshold



Diagnostic Fault Information