2010 Cadillac CTS Sedan AWD V6-3.6L Page 576
Conditions for Running the DTC
Battery voltage is between 9-16 volts.
Conditions for Setting the DTC
The BCM detects a fault in the trunk release relay control circuit.
Action Taken When the DTC Sets
The rear compartment latch will not operate.
Conditions for Clearing the DTC
* The DTC will be current for as long as the fault is present.
* When the fault is no longer present, the DTC will be a history DTC.
* A history DTC will clear after 50 ignition cycles
Reference Information
Schematic Reference
Release Systems Schematics (See: Body and Frame/Locks/Diagrams/Electrical Diagrams/Release Systems Schematics)
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Description and Operation
Luggage Compartment Description and Operation (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Description and Operation)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit
Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Wiring Repairs/Wiring Repairs)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
Ignition ON, command the trunk release with a scan tool. The rear compartment lid latch should release the trunk lid.
Circuit/System Testing
1. Ignition OFF, disconnect the TRUNK/RELSE relay.
2. Test for less than 5 ohms between the ground circuit terminal 85 and ground.
瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.
3. Connect a test lamp between the control circuit terminal 86 and the ground circuit terminal 85.
4. Ignition ON, command the trunk release ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the
commanded states.
瀚慖f the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
瀚慖f the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace
the BCM.
5. If all circuits test normal, test or replace the TRUNK/RELSE relay.
Component Testing
Relay Test
1. Ignition OFF, disconnect the TRUNK/RELSE relay.
2. Test for 60-180 ohms between terminals 85 and 86.