* The system voltage is between 9-16 volts.

* The vehicle power mode master requires serial data communication to occur.

Conditions for Setting the DTC

The BCM senses a short to ground on the accessory wake up serial data circuit.

Action Taken When the DTC Sets

* The modules use a default value for the missing parameters until the next ignition cycle.

* The module(s) is never signaled, therefore the specific subsystem(s) will not function.

* The vehicle may not start.

Conditions for Clearing the DTC

* A current DTC clears when the malfunction is no longer present.

* A history DTC clears when the module ignition cycle counter reaches the reset threshold of 50, without a repeat of the malfunction.

Diagnostic Aids

Short to ground may also set multiple no communication codes for GMLAN high speed modules.

Reference Information

Schematic Reference

* DLIS Fuse and Ignition Switch in Power Distribution Schematics (See: Diagrams/Electrical Diagrams/Starting and Charging/Power and

Ground Distribution/System Diagram/Power Distribution Schematics)

* Body Control System Schematics (See: Body and Frame/Body Control Systems/Diagrams/Electrical Diagrams)

* Data Communication Schematics (See: Powertrain Management/Computers and Control Systems/Information Bus/Diagrams/Electrical

Diagrams)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Data Link Communications Description and Operation (See: Powertrain Management/Computers and Control Systems/Information

Bus/Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Circuit/System Testing

1. With the ignition OFF, disconnect the module harness connectors listed below one at a time. After each disconnect, retest for current DTCs.

DTC U1814 should remain current.

* Engine control module (ECM) - X1

* Transmission control module (TCM) - X1

* Transfer case control module (TCCM) (RPO NP8) - X2

* Serial data gateway module (SDGM) (RPO HP2) - X2

瀚慖f the DTC becomes history, replace the module disconnected before the DTC became history.

2. Ignition OFF, disconnect the X4 harness connector at the BCM.

3. Test for infinite resistance between the accessory wake up serial data circuit terminal 19 and ground.

瀚慖f less than the specified range, test the serial data circuit for a short to ground.

4. If the circuit tests normal, replace the BCM.