2010 Cadillac CTS Sedan AWD V6-3.0L Page 1938
Connector End View Reference
Component Connector End Views (See: Diagrams/Connector Views)
Electrical Information Reference
* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit Testing/Circuit Testing)
* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Connector Repairs/Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit
Testing/Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Wiring Repairs/Wiring Repairs)
* Heated Oxygen Sensor Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Wiring Repairs/Heated
Oxygen Sensor Wiring Repairs)
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions (See: Diagnostic Trouble Code Descriptions/Powertrain Diagnostic Trouble Code
(DTC) Type Definitions)
Scan Tool Reference
Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information
Circuit/System Verification
1. Ignition ON, observe the DTC information with a scan tool. Verify no B52 HO2S heater DTCs are set.
瀚慖f a B52 HO2S heater DTC is set, refer to Diagnostic Trouble Code (DTC) List - Vehicle (See: Diagnostic Trouble Code
Descriptions/Diagnostic Trouble Code (DTC) List - Vehicle).
2. Engine running, observe the appropriate scan tool B52 HO2S voltage parameter. The reading should be within the range of 50-1,050 mV.
3. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the
conditions that you observed from the Freeze Frame/Failure Records data.
Circuit/System Testing
1. Ignition OFF, disconnect the appropriate B52 HO2S harness connector.
2. Ignition ON, observe the appropriate scan tool HO2S voltage parameter. The parameter should display 1.27 V.
瀚慖f less than the specified range, test the high and low signal circuits for a short to ground. If both signal circuit test normal, replace the
K20 ECM.
3. Ignition ON, test for 2.5-3.0 V between the high signal circuit terminal B and ground.
瀚慖f less than the specified range, test the high signal circuit for an open/high resistance. If the circuit tests normal, replace the K20 ECM.
瀚慖f greater than the specified range, test the high signal circuit for a short to voltage. If the circuit tests normal, replace the K20 ECM.
4. Ignition OFF, connect a 3 A fused jumper wire between the high signal circuit terminal B and the low signal circuit terminal A.
Note: The low signal circuit is tied to a pull-up circuit within the ECM. A voltage of 0.90-1.10 V on the low signal circuit is normal.
5. Ignition ON, verify the scan tool HO2S parameter displays 0.0 V.
瀚慖f greater than the specified range, test the low signal circuit for an open/high resistance or for a short to voltage. If the circuit tests
normal, replace the K20 ECM.
6. If all circuits test normal, test or replace the appropriate B52 HO2S.
Repair Instructions
Caution: Refer to Heated Oxygen Sensor Resistance Learn Reset Caution (See: Powertrain Management/Computers and Control
Systems/Oxygen Sensor/Service Precautions/Heated Oxygen Sensor Resistance Learn Reset Caution).
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
* Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 (LF1) (See: Powertrain Management/Computers and Control Systems/Oxygen
Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 (LLT) (See: Powertrain Management/Computers and
Control Systems/Oxygen Sensor/Service and Repair)
* Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 (LF1) (See: Powertrain Management/Computers and Control Systems/Oxygen
Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 (LLT) (See: Powertrain Management/Computers and
Control Systems/Oxygen Sensor/Service and Repair)
* Control Module References (See: Testing and Inspection/Programming and Relearning) for ECM replacement, setup, and programming