Thursday, June 11, 2020

2010 Cadillac Truck Escalade RWD V8-6.2L Page 1542

2010 Cadillac Truck Escalade RWD V8-6.2L Page 1542

Reference Information

Schematic Reference

Hybrid Energy Storage Schematics ()

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

DTC Type Reference

Diagnostic Trouble Code (DTC) List - Vehicle (See: Diagnostic Trouble Code Descriptions/Diagnostic Trouble Code (DTC) List - Vehicle)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Special Tools

* EL-48571 High Voltage Battery Pin Out Box

* EL-48900 HEV Safety Kit

Circuit/System Verification

1. Verify that DTC P0B3C, P0B3D, P0B3E, P0B41, P0B42, P0B43, P0B46, P0B47, P0B48, P0B4B, P0B4C, P0B4D, P0B50, P0B51, P0B52,

P0B55, P0B56, P0B57, P0B5A, P0B5B, P0B5C, P0B5F, P0B60, P0B61, P0B64, P0B65, P0B66, P0B69, P0B6A, P0B6B, P0B6E, P0B6F,

P0B70, P0B73, P0B74, P0B75, P0B78, P0B79, P0B7A, P0B7D, P0B7E, P0B7F, P0B82, P0B83, P0B84, P0B87, P0B88, P0B89, P0B8C,

P0B8D, P0B8E, P0B91, P0B92, P0B93, P0B96, P0B97, P0B98, P0B9B, P0B9C, P0B9D, or P0ABB is not set.

瀚慖f any of the DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle (See: Diagnostic Trouble Code

Descriptions/Diagnostic Trouble Code (DTC) List - Vehicle).

2. Ignition ON, engine OFF, verify the scan tool Hybrid Battery Pack Calculated Voltage parameter is 230-407 V.

3. Observe the scan tool Hybrid Battery 1-20 parameters. Each reading should be between 10-19 V and all readings should be within 1.5 V of

each other.

Circuit/System Testing

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection.

Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

* Identify how to disable high voltage.

* Identify how to test for the presence of high voltage.

* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures

must be followed.

Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:

* Safety glasses with appropriate side shields when within 50 feet of the vehicle, either indoors or outdoors.

* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.

- Visually and functionally inspect the gloves before use.

- Wear the Insulation gloves at all times when working with the high voltage battery assembly, whether the system is energized or

not.

Failure to follow the procedures exactly as written may result in serious injury or death.

1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling ().