Showing posts with label Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic repair.. Show all posts
Showing posts with label Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic repair.. Show all posts

Tuesday, June 2, 2020

2010 Cadillac Truck SRX AWD V6-3.0L Page 560

2010 Cadillac Truck SRX AWD V6-3.0L Page 560



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic repair.



* Liftgate Release Switch Replacement (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Trunk / Liftgate Switch/Service and



Repair/Liftgate Release Switch Replacement)



* Control Module References (See: Testing and Inspection/Programming and Relearning)for BCM replacement, setup and programming



Liftgate Handle Switch Malfunction



Liftgate Handle Switch Malfunction - DTC B2494



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.



DTC Descriptor



DTC B2494 02



- Liftgate Handle Switch Circuit Short to Ground



Diagnostic Fault Information



Circuit/System Description



The power liftgate handle switch circuit provides a single input to the liftgate control module. The liftgate handle switch is supplied a signal



voltage, when the switch contact closes and the voltage drops, the liftgate control module detects the voltage drop and commands the liftgate to



release.



Conditions for Running the DTC



The system voltage is 9-16 V.



Conditions for Setting the DTC



The liftgate handle switch signal circuit is active for greater than 30 seconds.



Action Taken When the DTC Sets



The liftgate control module will ignore the signal from the liftgate handle switch. Normal power liftgate operation will be available from the interior



liftgate control switch or from a request from the remote keyless entry module.



Conditions for Clearing the DTC



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Diagnostic Aids



* If the liftgate will not release from the closed position, refer to Opening the Liftgate Without Electrical Power (See: Body and Frame/Doors,



Hood and Trunk/Trunk / Liftgate/Service and Repair/Procedures) for the appropriate procedure



* Whenever the liftgate control module loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the



liftgate control module.



Reference Information



Schematic Reference



Liftgate Schematics (See: Body and Frame/Locks/Diagrams/Electrical Diagrams/Liftgate Schematics)

Thursday, February 20, 2020

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 231

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 231



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic repair.



* Liftgate Latch Replacement (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Trunk / Liftgate Latch/Service and Repair)



* Control Module References (See: Testing and Inspection/Programming and Relearning) for the liftgate control module replacement, setup



and programming



B153E



Liftgate Angle Sensor Malfunction - DTC B153E



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.



DTC Descriptor



DTC B153E 08



- Power Liftgate Angle Sensor - External Signal Invalid



Diagnostic Fault Information



Circuit/System Description



The liftgate control module continuously monitors power liftgate operation and calculates its location and direction of travel using 2 inputs from the



liftgate position sensor. One input returns the position of the liftgate relative to the latch along the x-axis and the other returns the position of the



liftgate relative to the latch along the y-axis. The liftgate control module then uses these 2 inputs together to calculate its angle relative to the



liftgate latch.



Conditions for Running the DTC



The system voltage is 9-16 V.



Conditions for Setting the DTC



The liftgate control module does not detect the angle inputs when the liftgate is in motion.



Action Taken When the DTC Sets



The liftgate will only be operational in the manual mode.



Conditions for Clearing the DTC



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Diagnostic Aids



Note: Before testing can be performed, the liftgate must be opened. Refer to Opening the Liftgate Without Electrical Power (See: Body and



Frame/Doors, Hood and Trunk/Trunk / Liftgate/Service and Repair/Procedures) for the appropriate procedure.



Whenever the liftgate module loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the liftgate module.

Sunday, February 2, 2020

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 560

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 560



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic repair.



* Liftgate Release Switch Replacement (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Trunk / Liftgate Switch/Service and



Repair/Liftgate Release Switch Replacement)



* Control Module References (See: Testing and Inspection/Programming and Relearning)for BCM replacement, setup and programming



Liftgate Handle Switch Malfunction



Liftgate Handle Switch Malfunction - DTC B2494



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.



DTC Descriptor



DTC B2494 02



- Liftgate Handle Switch Circuit Short to Ground



Diagnostic Fault Information



Circuit/System Description



The power liftgate handle switch circuit provides a single input to the liftgate control module. The liftgate handle switch is supplied a signal



voltage, when the switch contact closes and the voltage drops, the liftgate control module detects the voltage drop and commands the liftgate to



release.



Conditions for Running the DTC



The system voltage is 9-16 V.



Conditions for Setting the DTC



The liftgate handle switch signal circuit is active for greater than 30 seconds.



Action Taken When the DTC Sets



The liftgate control module will ignore the signal from the liftgate handle switch. Normal power liftgate operation will be available from the interior



liftgate control switch or from a request from the remote keyless entry module.



Conditions for Clearing the DTC



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Diagnostic Aids



* If the liftgate will not release from the closed position, refer to Opening the Liftgate Without Electrical Power (See: Body and Frame/Doors,



Hood and Trunk/Trunk / Liftgate/Service and Repair/Procedures) for the appropriate procedure



* Whenever the liftgate control module loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the



liftgate control module.



Reference Information



Schematic Reference



Liftgate Schematics (See: Body and Frame/Locks/Diagrams/Electrical Diagrams/Liftgate Schematics)