Sunday, July 5, 2020

2010 Cadillac Truck Escalade RWD V8-6.2L Page 2120

2010 Cadillac Truck Escalade RWD V8-6.2L Page 2120

A malfunction within the refrigerant system causing high pressure can cause this DTC to set.

Reference Information

Schematic Reference

HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams/HVAC - Automatic)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

* Air Temperature Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air

Temperature Description and Operation)

* Air Delivery Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic/Air Delivery

Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Verification

Ignition ON, observe the scan tool A/C Pressure Sensor parameter. The reading should be between 14.96 kPa and 3295 kPa and change with A/C

refrigerant pressure changes.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the A/C refrigerant pressure sensor.

2. Ignition OFF, test for less than 10 ohms between the low reference circuit terminal 1 and ground.

瀚慖f greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.

3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 2 and ground.

瀚慖f less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal,

replace the ECM.

瀚慖f greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.

4. Verify the scan tool A/C High Side Pressure Sensor parameter is less than 14.96 kPa.

瀚慖f greater than the specified range, test the signal circuit terminal 3 for a short to voltage. If the circuit tests normal, replace the ECM.

5. Install a 3A fused jumper wire between the signal circuit terminal 3 and the 5-volt reference circuit terminal 2. Verify the scan tool A/C High

Side Pressure Sensor parameter is greater than 3295 kPa.

瀚慖f less than the specified range, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the

ECM.

6. If all circuits test normal, test or replace the A/C refrigerant pressure sensor.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

* Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement (Non-HP2) (See: Heating and Air Conditioning/Refrigerant Pressure

Sensor / Switch/Service and Repair/Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement)Air Conditioning (A/C) Refrigerant

Pressure Sensor Replacement (HP2) (See: Heating and Air Conditioning/Refrigerant Pressure Sensor / Switch/Service and Repair/Air

Conditioning (A/C) Refrigerant Pressure Sensor Replacement)