3. Ignition ON.

4. Retest for DTCs P1A4F, P1A50, P1A51, P1A52, P1A53, P1A54, P1ADC and P1ADD.

Circuit/System Testing

Program the PIM with the latest software version and recheck for DTCs.

If the DTC resets after programming or if the PIM already contains the latest software version, replace the PIM.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

Control Module References (See: Testing and Inspection/Programming and Relearning) for PIM replacement, setup, and programming.

P1ADD

DTC P1A4F, P1A50-P1A54, P1ADC, or P1ADD

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System

Check - Vehicle) prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an

overview of the diagnostic approach.

* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure

Instructions) provides an overview of each diagnostic category.

DTC Descriptor

DTC P1A4F

- Drive Motor 1 Control Module Not Programmed

DTC P1A50

- Drive Motor 1 Control Module Random Access Memory (RAM)

DTC P1A51

- Drive Motor 1 Control Module Read Only Memory (ROM)

DTC P1A52

- Drive Motor 2 Control Module Not Programmed

DTC P1A53

- Drive Motor 2 Control Module Random Access Memory (RAM)

DTC P1A54

- Drive Motor 2 Control Module Read Only Memory (ROM)

DTC P1ADC

- Drive Motor 1 Control Module Long Term Memory Performance

DTC P1ADD

- Drive Motor 2 Control Module Long Term Memory Performance

Circuit/System Description

This is an internal fault detection of the Power Inverter Module (PIM). This fault is handled inside the PIM and no external circuits are involved.

Conditions for Running the DTC

* The control module runs the program to detect an internal fault when the key is ON.

* Ignition voltage is 8-18V.

Conditions for Setting the DTC

The control module has detected an internal malfunction.

Action Taken When the DTC Sets