Thursday, June 11, 2020

2010 Cadillac Truck Escalade RWD V8-6.2L Page 1545

2010 Cadillac Truck Escalade RWD V8-6.2L Page 1545

each other.

Circuit/System Testing

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection.

Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

* Identify how to disable high voltage.

* Identify how to test for the presence of high voltage.

* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures

must be followed.

Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:

* Safety glasses with appropriate side shields when within 50 feet of the vehicle, either indoors or outdoors.

* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.

- Visually and functionally inspect the gloves before use.

- Wear the Insulation gloves at all times when working with the high voltage battery assembly, whether the system is energized or

not.

Failure to follow the procedures exactly as written may result in serious injury or death.

1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling ().

2. Test for 230-407 V between the high voltage positive terminal X2 at the high voltage positive contactor and the high voltage negative

terminal X2 at the high voltage negative contactor.

瀚慖f the voltage is less than 194 V, replace the drive motor generator battery.

瀚慖f the voltage is between 194-230 V, perform the jump assist. Refer to Jump Assist ().

瀚慖f the voltage is greater than 407 V, replace the drive motor generator battery control module.

3. Disconnect the X4 harness connector at the drive motor generator battery control module.

4. Connect the EL-48571 high voltage battery pin out box.

5. Install the high voltage manual disconnect lever. Measure and record each of the 20 battery voltages.

6. Each battery voltage reading should be between 10-19 V.

瀚慖f not within the specified range, replace the drive motor battery assembly.

7. Each battery voltage reading should be within 1.5 V of each other.

瀚慖f not within the specified range, replace the drive motor battery assembly.

8. If all circuits test normal, replace the drive motor generator battery control module.

Repair Instructions

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the repair.

* Drive Motor Generator Battery Replacement and Shipping Preparation ()

* Control Module References (See: Testing and Inspection/Programming and Relearning) for drive motor generator battery control module

replacement, setup and programming

P1A4F

DTC P1A4F, P1A50-P1A54, P1ADC, or P1ADD

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System

Check - Vehicle) prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an

overview of the diagnostic approach.

* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure