Friday, March 20, 2020

2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 3185

2010 Cadillac Truck Escalade RWD V8-6.0L Hybrid Page 3185

Conditions for Running the DTC

* The system voltage is between 9-18 volts.

* Ignition key OFF.

Conditions for Setting the DTC

The BECM receives voltage from the BCM on wake up signal circuit 5986 for 3 seconds with the ignition OFF.

Action Taken When the DTC Sets

The hybrid powertrain control module (HPCM) will set DTC U209D.

Conditions for Clearing the DTC

* A current DTC clears when the malfunction is no longer present, including a key ON condition when both wake up signals are energized.

* A history DTC clears when the module ignition cycle counter reaches the reset threshold of 50, without a repeat of the malfunction.

Diagnostic Aids

* DTC U209D will only set as current with the ignition in the OFF position. It will become history when the ignition is turned ON.

* When testing circuits to the SDGM access can be accomplished by removing the instrument panel center trim panel. Note that this procedure

does not allow removal of the SDGM, only access to the connector. Refer to Instrument Panel Center Trim Panel Replacement (Cadillac) (

See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel Center Trim Panel

Replacement (Cadillac))Instrument Panel Center Trim Panel Replacement (Except Cadillac) (See: Body and Frame/Interior Moulding /

Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel Center Trim Panel Replacement (Except Cadillac)).

* Different DTCs may set in different modules along with this DTC depending on where the fault occurs and the vehicle operating conditions

when the fault occurs.

Reference Information

Schematic Reference

* Data Communication Schematics (See: Powertrain Management/Computers and Control Systems/Information Bus/Diagrams/Electrical

Diagrams)

* Control Module References (See: Testing and Inspection/Programming and Relearning)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Data Link Communications Description and Operation (See: Powertrain Management/Computers and Control Systems/Information

Bus/Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Circuit/System Testing

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal

Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

* Identify how to disable high voltage.

* Identify how to test for the presence of high voltage.

* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must

be followed.

Failure to follow the procedures exactly as written may result in serious injury or death.