Conditions for Clearing the DTC



The condition for setting the DTC is no longer present.



Reference Information



Schematic Reference



HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)



Description and Operation



Automatic HVAC Description and Operation (See: Heating and Air Conditioning/Description and Operation)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information



Circuit/System Testing



1. Ignition OFF, disconnect the harness connector at the B108 Air Quality Sensor.



2. Test for less than 10 ohm between the ground circuit terminal 2 and ground.



瀚慖f greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, replace the K33 HVAC



Control Module.



3. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 1 and ground.



瀚慖f the test lamp does not illuminate, test the ignition circuit for a short to ground or a open/high resistance. If the circuit tests normal,



replace the K33 HVAC Control Module.



4. Verify the scan tool Odor Sensor parameter is greater than 95%.



瀚慖f less than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the K33 HVAC Control



Module.



5. Install a 3 A fused jumper wire between the following signal circuit terminal 3 and the ground circuit terminal 2. Verify the scan tool Odor



Sensor parameter is less than 5%.



瀚慖f greater than the specified range, test the signal circuit for a short to voltage or open/high resistance. If the circuit tests normal, replace



the K33 HVAC Control Module.



6. If all circuits test normal, replace the B108 Air Quality Sensor.



Repair Instructions



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.



* HVAC Component Replacement Reference (See: Heating and Air Conditioning/Service and Repair/Removal and Replacement)



* Control Module References (See: Testing and Inspection/Programming and Relearning) for HVAC Control Module replacement, setup, and



programming



B3849



DTC B3849



Diagnostic Instructions