Friday, January 3, 2020

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 922

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 922



Circuit/System Verification



Note: The engine oil level and the oil pressure are critical to the correct operation of the camshaft position actuator system. Verify that the



engine has the correct oil level and the correct oil pressure before continuing with this diagnostic.



1. Ignition ON, observe the scan tool DTC information. Verify that none of the following DTCs are set. DTC P0016, P0017, P0018, P0019,



P0335, P0336, P0338, P0341, P0342, P0343, P0346, P0347, P0348, P0366, P0367, P0368, P0391, P0392, P0393, P0521, P0522, P0523,



P0638, P2100, P2101, P2102, P2103, or P2119.



瀚慖f any of the DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle (See: Diagnostic Trouble Code



Descriptions/Diagnostic Trouble Code (DTC) List - Vehicle) for further diagnosis.



2. Engine idling, command the appropriate Camshaft Position Actuator from 0 degrees to 40 degrees and back to zero while observing the



appropriate scan tool Camshaft Position Variance parameters. The Camshaft Position Variance should be less than 2 degrees in each of the



commanded states.



3. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the



conditions that you observed from the Freeze Frame/Failure Records data.



Circuit/System Testing



1. Ignition OFF, disconnect the harness connector at the appropriate Q6 Camshaft Position Actuator Solenoid Valve.



2. Ignition ON, load test for B+ between the ignition circuit terminal 1 and ground.



瀚慖f less than the specified range, test the ignition voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal



and the ignition circuit fuse is open, test all the components connected to the ignition circuit and replace as necessary.



Note: Use the J 35616-200 - Test Lamp Kit for this test. If the J 35616-200 - Test Lamp Kit is not available, use a test lamp that measures



greater than 20 ohm.



3. Connect a test lamp between the control circuit terminal 2 and B+.



Note: The voltage must be measured at the control side of the circuit.



4. Command the appropriate Camshaft Position Actuator Solenoid Valve ON with a scan tool. Load test for less than 1 V between the control



circuit terminal 2 and ground.



瀚慖f greater than the specified range, test the control circuit for an open/high resistance. If the circuit/connections test normal, replace the



K20 Engine Control Module.



5. Remove the Camshaft Position Actuator Solenoid Valve. Inspect the Camshaft Position Actuator Solenoid Valve and mounting area for the



following conditions:



* For a torn, restricted, mis-positioned, or missing screens at the Camshaft Position Actuator Solenoid Valve



* For engine oil leaks between the oil sealing lands of the Camshaft Position Actuator Solenoid Valve. Inspect the lands of the Camshaft



Position Actuator Solenoid Valve for nicks



* For oil seepage at the Camshaft Position Actuator Solenoid Valve connector



瀚慖f a condition is found, replace Q6 Camshaft Position Actuator Solenoid Valve.



6. Ignition OFF, swap the appropriate Camshaft Position Actuator Solenoid Valve with a Camshaft Position Actuator Solenoid Valve that is



operating correctly.



7. Engine idling. Command the appropriate Camshaft Position Actuator from 0 degrees to 40 degrees and back to zero while observing the



appropriate scan tool Camshaft Position Variance parameters. The Camshaft Position Variance should be less than 2 degrees in each of the



commanded states.



瀚慖f greater than the specified value, replace the mechanical camshaft position actuator.



8. If all circuits/connections test normal, test or replace the Q6 Camshaft Position Actuator Solenoid Valve.



Component Testing



1. Ignition OFF, disconnect the harness connector at the appropriate Q6 Camshaft Position Actuator Solenoid Valve.



2. Test for 7-12 ohm between the control terminal 2 and the ignition terminal 1 of the Q6 Camshaft Position Actuator Solenoid Valve.



瀚慖f not within the specified range, replace the Q6 Camshaft Position Actuator Solenoid Valve.



3. Test for infinite resistance between each terminal and the Q6 Camshaft Position Actuator Solenoid Valve housing.



瀚慖f not the specified value, replace the Q6 Camshaft Position Actuator Solenoid Valve.