A malfunction within the refrigerant system causing high pressure can cause this DTC to set.



Reference Information



Schematic Reference



HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views)



Description and Operation



Automatic HVAC Description and Operation (See: Heating and Air Conditioning/Description and Operation/HVAC - Automatic)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit



Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/Wiring Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information



Circuit/System Verification



Ignition ON, observe the scan tool A/C Pressure Sensor parameter. The reading should be between 0.1 volts (1 psi) and 4.90 volts (425 psi) and



change with A/C refrigerant pressure changes.



Circuit/System Testing



1. Ignition OFF, disconnect the harness connector at the A/C refrigerant pressure sensor.



2. Ignition OFF, test for less than 10 ohms between the low reference circuit terminal 1 and ground.



瀚慖f greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.



3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 2 and ground.



瀚慖f less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal,



replace the ECM.



瀚慖f greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.



4. Verify the scan tool A/C High Side Pressure Sensor parameter is less than 0.1 volts (1 psi).



瀚慖f greater than the specified range, test the signal circuit terminal 3 for a short to voltage. If the circuit tests normal, replace the ECM.



5. Install a 3A fused jumper wire between the signal circuit terminal 3 and the 5-volt reference circuit terminal 2. Verify the scan tool A/C High



Side Pressure Sensor parameter is greater than 4.90 volts (425 psi).



瀚慖f less than the specified range, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the



ECM.



6. If all circuits test normal, test or replace the A/C refrigerant pressure sensor.



Repair Instructions



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.



* Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement (See: Heating and Air Conditioning/Refrigerant Pressure Sensor /



Switch/Service and Repair)



* Control Module References (See: Testing and Inspection/Programming and Relearning) for ECM replacement, setup, and programming



6L45/6L50/6L80/6L90 - Automatic Transmission



DTC P0562 or P0563



Diagnostic Instructions