Monday, December 23, 2019

2010 Cadillac Truck Escalade AWD V8-6.2L Page 2627

锟斤拷If you find any of the above conditions, repair as necessary.

6. If all circuits test normal, replace the appropriate B52 HO2S.

Repair Instructions

Caution: Refer to Heated Oxygen Sensor Resistance Learn Reset Caution (See: Powertrain Management/Computers and Control

Systems/Oxygen Sensor/Service Precautions/Heated Oxygen Sensor Resistance Learn Reset Caution).

Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.

* Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 (1500 Series) (See: Powertrain Management/Computers and Control

Systems/Oxygen Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 (2500 Series) (See: Powertrain

Management/Computers and Control Systems/Oxygen Sensor/Service and Repair)

* Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 (1500 Series) (See: Powertrain Management/Computers and Control

Systems/Oxygen Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 (2500 Series) (See: Powertrain

Management/Computers and Control Systems/Oxygen Sensor/Service and Repair)

* Control Module References (See: Testing and Inspection/Programming and Relearning) for ECM replacement, setup, and programming

P2271

DTC P2271 or P2273

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System

Check - Vehicle) prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an

overview of the diagnostic approach.

* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure

Instructions) provides an overview of each diagnostic category.

DTC Descriptors

DTC P2271

- HO2S Signal Stuck Rich Bank 1 Sensor 2

DTC P2273

- HO2S Signal Stuck Rich Bank 2 Sensor 2

Diagnostic Fault Information

Typical Scan Tool Data

Circuit/System Description

Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding